forked from kcsinclair/mibs
-
Notifications
You must be signed in to change notification settings - Fork 0
/
BRIDGE-MIB.my
1503 lines (1325 loc) · 54 KB
/
BRIDGE-MIB.my
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
-- ----------------------------------------------------------------
-- BRIDGE-MIB.my Definitions of Managed Objects for Bridges
--
-- Copyright (c) 2008 by cisco Systems, Inc.
-- All rights reserved.
--
-- Extracted from RFC-4188
-- Mar, 2008 Sudheer Reddy Thati
--
-- ----------------------------------------------------------------
BRIDGE-MIB DEFINITIONS ::= BEGIN
-- ---------------------------------------------------------- --
-- MIB for IEEE 802.1D devices
-- ---------------------------------------------------------- --
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Counter32, Integer32, TimeTicks, mib-2
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, MacAddress
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
InterfaceIndex FROM IF-MIB
;
dot1dBridge MODULE-IDENTITY
LAST-UPDATED "200509190000Z"
ORGANIZATION "IETF Bridge MIB Working Group"
CONTACT-INFO
"Email: [email protected]
K.C. Norseth (Editor)
L-3 Communications
Tel: +1 801-594-2809
Email: [email protected]
Postal: 640 N. 2200 West.
Salt Lake City, Utah 84116-0850
Les Bell (Editor)
3Com Europe Limited
Phone: +44 1442 438025
Email: [email protected]
Postal: 3Com Centre, Boundary Way
Hemel Hempstead
Herts. HP2 7YU
UK
Send comments to <[email protected]>"
DESCRIPTION
"The Bridge MIB module for managing devices that support
IEEE 802.1D.
Copyright (C) The Internet Society (2005). This version of
this MIB module is part of RFC 4188; see the RFC itself for
full legal notices."
REVISION "200509190000Z"
DESCRIPTION
"Third revision, published as part of RFC 4188.
The MIB module has been converted to SMIv2 format.
Conformance statements have been added and some
description and reference clauses have been updated.
The object dot1dStpPortPathCost32 was added to
support IEEE 802.1t and the permissible values of
dot1dStpPriority and dot1dStpPortPriority have been
clarified for bridges supporting IEEE 802.1t or
IEEE 802.1w.
The interpretation of dot1dStpTimeSinceTopologyChange
has been clarified for bridges supporting the Rapid
Spanning Tree Protocol (RSTP)."
REVISION "199307310000Z"
DESCRIPTION
"Second revision, published as part of RFC 1493."
REVISION "199112310000Z"
DESCRIPTION
"Initial revision, published as part of RFC 1286."
::= { mib-2 17 }
-- ---------------------------------------------------------- --
-- Textual Conventions
-- ---------------------------------------------------------- --
BridgeId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Bridge-Identifier, as used in the Spanning Tree
Protocol, to uniquely identify a bridge. Its first two
octets (in network byte order) contain a priority value,
and its last 6 octets contain the MAC address used to
refer to a bridge in a unique fashion (typically, the
numerically smallest MAC address of all ports on the
bridge)."
SYNTAX OCTET STRING (SIZE (8))
Timeout ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A Spanning Tree Protocol (STP) timer in units of 1/100
seconds. Several objects in this MIB module represent
values of timers used by the Spanning Tree Protocol.
In this MIB, these timers have values in units of
hundredths of a second (i.e., 1/100 secs).
These timers, when stored in a Spanning Tree Protocol's
BPDU, are in units of 1/256 seconds. Note, however, that
802.1D-1998 specifies a settable granularity of no more
than one second for these timers. To avoid ambiguity,
a conversion algorithm is defined below for converting
between the different units, which ensures a timer's
value is not distorted by multiple conversions.
To convert a Timeout value into a value in units of
1/256 seconds, the following algorithm should be used:
b = floor( (n * 256) / 100)
where:
floor = quotient [ignore remainder]
n is the value in 1/100 second units
b is the value in 1/256 second units
To convert the value from 1/256 second units back to
1/100 seconds, the following algorithm should be used:
n = ceiling( (b * 100) / 256)
where:
ceiling = quotient [if remainder is 0], or
quotient + 1 [if remainder is nonzero]
n is the value in 1/100 second units
b is the value in 1/256 second units
Note: it is important that the arithmetic operations are
done in the order specified (i.e., multiply first,
divide second)."
SYNTAX Integer32
-- ---------------------------------------------------------- --
-- subtrees in the Bridge MIB
-- ---------------------------------------------------------- --
dot1dNotifications OBJECT IDENTIFIER ::= { dot1dBridge 0 }
dot1dBase OBJECT IDENTIFIER ::= { dot1dBridge 1 }
dot1dStp OBJECT IDENTIFIER ::= { dot1dBridge 2 }
dot1dSr OBJECT IDENTIFIER ::= { dot1dBridge 3 }
-- documented in RFC 1525
dot1dTp OBJECT IDENTIFIER ::= { dot1dBridge 4 }
dot1dStatic OBJECT IDENTIFIER ::= { dot1dBridge 5 }
-- Subtrees used by Bridge MIB Extensions:
-- pBridgeMIB MODULE-IDENTITY ::= { dot1dBridge 6 }
-- qBridgeMIB MODULE-IDENTITY ::= { dot1dBridge 7 }
-- Note that the practice of registering related MIB modules
-- below dot1dBridge has been discouraged since there is no
-- robust mechanism to track such registrations.
dot1dConformance OBJECT IDENTIFIER ::= { dot1dBridge 8 }
-- ---------------------------------------------------------- --
-- the dot1dBase subtree
-- ---------------------------------------------------------- --
-- Implementation of the dot1dBase subtree is mandatory for all
-- bridges.
-- ---------------------------------------------------------- --
dot1dBaseBridgeAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address used by this bridge when it must be
referred to in a unique fashion. It is recommended
that this be the numerically smallest MAC address of
all ports that belong to this bridge. However, it is only
required to be unique. When concatenated with
dot1dStpPriority, a unique BridgeIdentifier is formed,
which is used in the Spanning Tree Protocol."
REFERENCE
"IEEE 802.1D-1998: clauses 14.4.1.1.3 and 7.12.5"
::= { dot1dBase 1 }
dot1dBaseNumPorts OBJECT-TYPE
SYNTAX Integer32
UNITS "ports"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ports controlled by this bridging
entity."
REFERENCE
"IEEE 802.1D-1998: clause 14.4.1.1.3"
::= { dot1dBase 2 }
dot1dBaseType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
transparent-only(2),
sourceroute-only(3),
srt(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates what type of bridging this bridge can
perform. If a bridge is actually performing a
certain type of bridging, this will be indicated by
entries in the port table for the given type."
::= { dot1dBase 3 }
-- ---------------------------------------------------------- --
-- The Generic Bridge Port Table
-- ---------------------------------------------------------- --
dot1dBasePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dBasePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains generic information about every
port that is associated with this bridge. Transparent,
source-route, and srt ports are included."
::= { dot1dBase 4 }
dot1dBasePortEntry OBJECT-TYPE
SYNTAX Dot1dBasePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information for each port of the bridge."
REFERENCE
"IEEE 802.1D-1998: clause 14.4.2, 14.6.1"
INDEX { dot1dBasePort }
::= { dot1dBasePortTable 1 }
Dot1dBasePortEntry ::=
SEQUENCE {
dot1dBasePort
Integer32,
dot1dBasePortIfIndex
InterfaceIndex,
dot1dBasePortCircuit
OBJECT IDENTIFIER,
dot1dBasePortDelayExceededDiscards
Counter32,
dot1dBasePortMtuExceededDiscards
Counter32
}
dot1dBasePort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number of the port for which this entry
contains bridge management information."
::= { dot1dBasePortEntry 1 }
dot1dBasePortIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the instance of the ifIndex object,
defined in IF-MIB, for the interface corresponding
to this port."
::= { dot1dBasePortEntry 2 }
dot1dBasePortCircuit OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For a port that (potentially) has the same value of
dot1dBasePortIfIndex as another port on the same bridge.
This object contains the name of an object instance
unique to this port. For example, in the case where
multiple ports correspond one-to-one with multiple X.25
virtual circuits, this value might identify an (e.g.,
the first) object instance associated with the X.25
virtual circuit corresponding to this port.
For a port which has a unique value of
dot1dBasePortIfIndex, this object can have the value
{ 0 0 }."
::= { dot1dBasePortEntry 3 }
dot1dBasePortDelayExceededDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames discarded by this port due
to excessive transit delay through the bridge. It
is incremented by both transparent and source
route bridges."
REFERENCE
"IEEE 802.1D-1998: clause 14.6.1.1.3"
::= { dot1dBasePortEntry 4 }
dot1dBasePortMtuExceededDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames discarded by this port due
to an excessive size. It is incremented by both
transparent and source route bridges."
REFERENCE
"IEEE 802.1D-1998: clause 14.6.1.1.3"
::= { dot1dBasePortEntry 5 }
-- ---------------------------------------------------------- --
-- the dot1dStp subtree
-- ---------------------------------------------------------- --
-- Implementation of the dot1dStp subtree is optional. It is
-- implemented by those bridges that support the Spanning Tree
-- Protocol.
-- ---------------------------------------------------------- --
dot1dStpProtocolSpecification OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
decLb100(2),
ieee8021d(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of what version of the Spanning Tree
Protocol is being run. The value 'decLb100(2)'
indicates the DEC LANbridge 100 Spanning Tree protocol.
IEEE 802.1D implementations will return 'ieee8021d(3)'.
If future versions of the IEEE Spanning Tree Protocol
that are incompatible with the current version
are released a new value will be defined."
::= { dot1dStp 1 }
dot1dStpPriority OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the write-able portion of the Bridge ID
(i.e., the first two octets of the (8 octet long) Bridge
ID). The other (last) 6 octets of the Bridge ID are
given by the value of dot1dBaseBridgeAddress.
On bridges supporting IEEE 802.1t or IEEE 802.1w,
permissible values are 0-61440, in steps of 4096."
REFERENCE
"IEEE 802.1D-1998 clause 8.10.2, Table 8-4,
IEEE 802.1t clause 8.10.2, Table 8-4, clause 14.3."
::= { dot1dStp 2 }
dot1dStpTimeSinceTopologyChange OBJECT-TYPE
SYNTAX TimeTicks
UNITS "centi-seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time (in hundredths of a second) since the
last time a topology change was detected by the
bridge entity.
For RSTP, this reports the time since the tcWhile
timer for any port on this Bridge was nonzero."
REFERENCE
"IEEE 802.1D-1998 clause 14.8.1.1.,
IEEE 802.1w clause 14.8.1.1."
::= { dot1dStp 3 }
dot1dStpTopChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of topology changes detected by
this bridge since the management entity was last
reset or initialized."
REFERENCE
"IEEE 802.1D-1998 clause 14.8.1.1."
::= { dot1dStp 4 }
dot1dStpDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The bridge identifier of the root of the spanning
tree, as determined by the Spanning Tree Protocol,
as executed by this node. This value is used as
the Root Identifier parameter in all Configuration
Bridge PDUs originated by this node."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.3.1"
::= { dot1dStp 5 }
dot1dStpRootCost OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cost of the path to the root as seen from
this bridge."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.3.2"
::= { dot1dStp 6 }
dot1dStpRootPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number of the port that offers the lowest
cost path from this bridge to the root bridge."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.3.3"
::= { dot1dStp 7 }
dot1dStpMaxAge OBJECT-TYPE
SYNTAX Timeout
UNITS "centi-seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum age of Spanning Tree Protocol information
learned from the network on any port before it is
discarded, in units of hundredths of a second. This is
the actual value that this bridge is currently using."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.3.4"
::= { dot1dStp 8 }
dot1dStpHelloTime OBJECT-TYPE
SYNTAX Timeout
UNITS "centi-seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time between the transmission of
Configuration bridge PDUs by this node on any port when
it is the root of the spanning tree, or trying to become
so, in units of hundredths of a second. This is the
actual value that this bridge is currently using."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.3.5"
::= { dot1dStp 9 }
dot1dStpHoldTime OBJECT-TYPE
SYNTAX Integer32
UNITS "centi-seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This time value determines the interval length
during which no more than two Configuration bridge
PDUs shall be transmitted by this node, in units
of hundredths of a second."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.3.14"
::= { dot1dStp 10 }
dot1dStpForwardDelay OBJECT-TYPE
SYNTAX Timeout
UNITS "centi-seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This time value, measured in units of hundredths of a
second, controls how fast a port changes its spanning
state when moving towards the Forwarding state. The
value determines how long the port stays in each of the
Listening and Learning states, which precede the
Forwarding state. This value is also used when a
topology change has been detected and is underway, to
age all dynamic entries in the Forwarding Database.
[Note that this value is the one that this bridge is
currently using, in contrast to
dot1dStpBridgeForwardDelay, which is the value that this
bridge and all others would start using if/when this
bridge were to become the root.]"
REFERENCE
"IEEE 802.1D-1998: clause 8.5.3.6"
::= { dot1dStp 11 }
dot1dStpBridgeMaxAge OBJECT-TYPE
SYNTAX Timeout (600..4000)
UNITS "centi-seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value that all bridges use for MaxAge when this
bridge is acting as the root. Note that 802.1D-1998
specifies that the range for this parameter is related
to the value of dot1dStpBridgeHelloTime. The
granularity of this timer is specified by 802.1D-1998 to
be 1 second. An agent may return a badValue error if a
set is attempted to a value that is not a whole number
of seconds."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.3.8"
::= { dot1dStp 12 }
dot1dStpBridgeHelloTime OBJECT-TYPE
SYNTAX Timeout (100..1000)
UNITS "centi-seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value that all bridges use for HelloTime when this
bridge is acting as the root. The granularity of this
timer is specified by 802.1D-1998 to be 1 second. An
agent may return a badValue error if a set is attempted
to a value that is not a whole number of seconds."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.3.9"
::= { dot1dStp 13 }
dot1dStpBridgeForwardDelay OBJECT-TYPE
SYNTAX Timeout (400..3000)
UNITS "centi-seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value that all bridges use for ForwardDelay when
this bridge is acting as the root. Note that
802.1D-1998 specifies that the range for this parameter
is related to the value of dot1dStpBridgeMaxAge. The
granularity of this timer is specified by 802.1D-1998 to
be 1 second. An agent may return a badValue error if a
set is attempted to a value that is not a whole number
of seconds."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.3.10"
::= { dot1dStp 14 }
-- ---------------------------------------------------------- --
-- The Spanning Tree Port Table
-- ---------------------------------------------------------- --
dot1dStpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dStpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains port-specific information
for the Spanning Tree Protocol."
::= { dot1dStp 15 }
dot1dStpPortEntry OBJECT-TYPE
SYNTAX Dot1dStpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information maintained by every port about
the Spanning Tree Protocol state for that port."
INDEX { dot1dStpPort }
::= { dot1dStpPortTable 1 }
Dot1dStpPortEntry ::=
SEQUENCE {
dot1dStpPort
Integer32,
dot1dStpPortPriority
Integer32,
dot1dStpPortState
INTEGER,
dot1dStpPortEnable
INTEGER,
dot1dStpPortPathCost
Integer32,
dot1dStpPortDesignatedRoot
BridgeId,
dot1dStpPortDesignatedCost
Integer32,
dot1dStpPortDesignatedBridge
BridgeId,
dot1dStpPortDesignatedPort
OCTET STRING,
dot1dStpPortForwardTransitions
Counter32,
dot1dStpPortPathCost32
Integer32
}
dot1dStpPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number of the port for which this entry
contains Spanning Tree Protocol management information."
REFERENCE
"IEEE 802.1D-1998: clause 14.8.2.1.2"
::= { dot1dStpPortEntry 1 }
dot1dStpPortPriority OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the priority field that is contained in
the first (in network byte order) octet of the (2 octet
long) Port ID. The other octet of the Port ID is given
by the value of dot1dStpPort.
On bridges supporting IEEE 802.1t or IEEE 802.1w,
permissible values are 0-240, in steps of 16."
REFERENCE
"IEEE 802.1D-1998 clause 8.10.2, Table 8-4,
IEEE 802.1t clause 8.10.2, Table 8-4, clause 14.3."
::= { dot1dStpPortEntry 2 }
dot1dStpPortState OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
blocking(2),
listening(3),
learning(4),
forwarding(5),
broken(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port's current state, as defined by application of
the Spanning Tree Protocol. This state controls what
action a port takes on reception of a frame. If the
bridge has detected a port that is malfunctioning, it
will place that port into the broken(6) state. For
ports that are disabled (see dot1dStpPortEnable), this
object will have a value of disabled(1)."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.5.2"
::= { dot1dStpPortEntry 3 }
dot1dStpPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The enabled/disabled status of the port."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.5.2"
::= { dot1dStpPortEntry 4 }
dot1dStpPortPathCost OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The contribution of this port to the path cost of
paths towards the spanning tree root which include
this port. 802.1D-1998 recommends that the default
value of this parameter be in inverse proportion to
the speed of the attached LAN.
New implementations should support dot1dStpPortPathCost32.
If the port path costs exceeds the maximum value of this
object then this object should report the maximum value,
namely 65535. Applications should try to read the
dot1dStpPortPathCost32 object if this object reports
the maximum value."
REFERENCE "IEEE 802.1D-1998: clause 8.5.5.3"
::= { dot1dStpPortEntry 5 }
dot1dStpPortDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unique Bridge Identifier of the Bridge
recorded as the Root in the Configuration BPDUs
transmitted by the Designated Bridge for the
segment to which the port is attached."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.5.4"
::= { dot1dStpPortEntry 6 }
dot1dStpPortDesignatedCost OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The path cost of the Designated Port of the segment
connected to this port. This value is compared to the
Root Path Cost field in received bridge PDUs."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.5.5"
::= { dot1dStpPortEntry 7 }
dot1dStpPortDesignatedBridge OBJECT-TYPE
SYNTAX BridgeId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Bridge Identifier of the bridge that this
port considers to be the Designated Bridge for
this port's segment."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.5.6"
::= { dot1dStpPortEntry 8 }
dot1dStpPortDesignatedPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Port Identifier of the port on the Designated
Bridge for this port's segment."
REFERENCE
"IEEE 802.1D-1998: clause 8.5.5.7"
::= { dot1dStpPortEntry 9 }
dot1dStpPortForwardTransitions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times this port has transitioned
from the Learning state to the Forwarding state."
::= { dot1dStpPortEntry 10 }
dot1dStpPortPathCost32 OBJECT-TYPE
SYNTAX Integer32 (1..200000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The contribution of this port to the path cost of
paths towards the spanning tree root which include
this port. 802.1D-1998 recommends that the default
value of this parameter be in inverse proportion to
the speed of the attached LAN.
This object replaces dot1dStpPortPathCost to support
IEEE 802.1t."
REFERENCE
"IEEE 802.1t clause 8.10.2, Table 8-5."
::= { dot1dStpPortEntry 11 }
-- ---------------------------------------------------------- --
-- the dot1dTp subtree
-- ---------------------------------------------------------- --
-- Implementation of the dot1dTp subtree is optional. It is
-- implemented by those bridges that support the transparent
-- bridging mode. A transparent or SRT bridge will implement
-- this subtree.
-- ---------------------------------------------------------- --
dot1dTpLearnedEntryDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of Forwarding Database entries that
have been or would have been learned, but have been
discarded due to a lack of storage space in the
Forwarding Database. If this counter is increasing, it
indicates that the Forwarding Database is regularly
becoming full (a condition that has unpleasant
performance effects on the subnetwork). If this counter
has a significant value but is not presently increasing,
it indicates that the problem has been occurring but is
not persistent."
REFERENCE
"IEEE 802.1D-1998: clause 14.7.1.1.3"
::= { dot1dTp 1 }
dot1dTpAgingTime OBJECT-TYPE
SYNTAX Integer32 (10..1000000)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout period in seconds for aging out
dynamically-learned forwarding information.
802.1D-1998 recommends a default of 300 seconds."
REFERENCE
"IEEE 802.1D-1998: clause 14.7.1.1.3"
::= { dot1dTp 2 }
-- ---------------------------------------------------------- --
-- The Forwarding Database for Transparent Bridges
-- ---------------------------------------------------------- --
dot1dTpFdbTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dTpFdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about unicast
entries for which the bridge has forwarding and/or
filtering information. This information is used
by the transparent bridging function in
determining how to propagate a received frame."
::= { dot1dTp 3 }
dot1dTpFdbEntry OBJECT-TYPE
SYNTAX Dot1dTpFdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a specific unicast MAC address
for which the bridge has some forwarding and/or
filtering information."
INDEX { dot1dTpFdbAddress }
::= { dot1dTpFdbTable 1 }
Dot1dTpFdbEntry ::=
SEQUENCE {
dot1dTpFdbAddress
MacAddress,
dot1dTpFdbPort
Integer32,
dot1dTpFdbStatus
INTEGER
}
dot1dTpFdbAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unicast MAC address for which the bridge has
forwarding and/or filtering information."
REFERENCE
"IEEE 802.1D-1998: clause 7.9.1, 7.9.2"
::= { dot1dTpFdbEntry 1 }
dot1dTpFdbPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Either the value '0', or the port number of the port on
which a frame having a source address equal to the value
of the corresponding instance of dot1dTpFdbAddress has
been seen. A value of '0' indicates that the port
number has not been learned, but that the bridge does
have some forwarding/filtering information about this
address (e.g., in the dot1dStaticTable). Implementors
are encouraged to assign the port value to this object
whenever it is learned, even for addresses for which the
corresponding value of dot1dTpFdbStatus is not
learned(3)."
::= { dot1dTpFdbEntry 2 }
dot1dTpFdbStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
learned(3),
self(4),
mgmt(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this entry. The meanings of the
values are:
other(1) - none of the following. This would
include the case where some other MIB object
(not the corresponding instance of
dot1dTpFdbPort, nor an entry in the
dot1dStaticTable) is being used to determine if
and how frames addressed to the value of the
corresponding instance of dot1dTpFdbAddress are
being forwarded.
invalid(2) - this entry is no longer valid (e.g.,
it was learned but has since aged out), but has
not yet been flushed from the table.
learned(3) - the value of the corresponding instance
of dot1dTpFdbPort was learned, and is being
used.
self(4) - the value of the corresponding instance of
dot1dTpFdbAddress represents one of the bridge's
addresses. The corresponding instance of
dot1dTpFdbPort indicates which of the bridge's
ports has this address.
mgmt(5) - the value of the corresponding instance of
dot1dTpFdbAddress is also the value of an
existing instance of dot1dStaticAddress."
::= { dot1dTpFdbEntry 3 }
-- ---------------------------------------------------------- --
-- Port Table for Transparent Bridges
-- ---------------------------------------------------------- --
dot1dTpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dTpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about every port that
is associated with this transparent bridge."
::= { dot1dTp 4 }
dot1dTpPortEntry OBJECT-TYPE
SYNTAX Dot1dTpPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information for each port of a transparent
bridge."
INDEX { dot1dTpPort }
::= { dot1dTpPortTable 1 }
Dot1dTpPortEntry ::=
SEQUENCE {
dot1dTpPort
Integer32,
dot1dTpPortMaxInfo
Integer32,
dot1dTpPortInFrames
Counter32,
dot1dTpPortOutFrames
Counter32,
dot1dTpPortInDiscards
Counter32
}
dot1dTpPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number of the port for which this entry
contains Transparent bridging management information."
::= { dot1dTpPortEntry 1 }
-- It would be nice if we could use ifMtu as the size of the
-- largest INFO field, but we can't because ifMtu is defined
-- to be the size that the (inter-)network layer can use, which
-- can differ from the MAC layer (especially if several layers
-- of encapsulation are used).
dot1dTpPortMaxInfo OBJECT-TYPE
SYNTAX Integer32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum size of the INFO (non-MAC) field that
this port will receive or transmit."
::= { dot1dTpPortEntry 2 }
dot1dTpPortInFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames that have been received by this
port from its segment. Note that a frame received on the
interface corresponding to this port is only counted by
this object if and only if it is for a protocol being
processed by the local bridging function, including
bridge management frames."
REFERENCE
"IEEE 802.1D-1998: clause 14.6.1.1.3"
::= { dot1dTpPortEntry 3 }
dot1dTpPortOutFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames that have been transmitted by this
port to its segment. Note that a frame transmitted on
the interface corresponding to this port is only counted
by this object if and only if it is for a protocol being
processed by the local bridging function, including
bridge management frames."
REFERENCE